Enhancement of Range Resolution using Two Receivers in Continuous Time Frequency Modulation Technique
Kapil Dev Tyagi
Kapil Dev Tyagi*, ECE department, Jaypee Institute of Information Technology, Noida, India.
Manuscript received on February 02, 2020. | Revised Manuscript received on February 10, 2020. | Manuscript published on March 30, 2020. | PP: 936-939 | Volume-8 Issue-6, March 2020. | Retrieval Number: E6647018520/2020©BEIESP | DOI: 10.35940/ijrte.E6647.038620
Open Access | Ethics and Policies | Cite | Mendeley
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
Abstract: The resolution in range in continuous time frequency modulation (CTFM) is directly proportional to the pulse width of the compressed signal. The two receiver technique for continuous transmission frequency modulation processing was proposed as a technique to make resolution independent of the pulse width. In two receiver technique the output is without any discontinuity in time. Practically, it has been observed that the resolution in range is also limited by the pulse width of the probe signal bandwidth in the two receiver CTFM technique. The actual performance and limitation of the two receiver technique has been given in this paper.
Keywords: Two receiver, Range-resolution, unperceptive-time.
Scope of the Article: Frequency selective surface.