Experimental and Analytical Behavior of Geopolymer Concrete Interior R.C. Beam Column Joint with Glass Fibres under Cyclic Loading
Lenkala. Krishna1, Rena Dedefo Buta2, SK.B B Ayesha3, Muktar Jeylan Alo4
1Lenkala.Krishna *, 1Assistant professor, Department. of Civil Engineering, Sri Indu college of Engineering & Technology (Autonomous), Sheriguda, Ibrahimpatnam, Hyderabad.
2Rena Dedefo Buta ,Lecturer, HOD, Department of Civil Engineering, Madda walabu University, Bale Robe, Ethiopia.
3
SK. B.B Ayesha, Assistant professor, Department. of Civil Engineering, Sri Indu college of Engineering & Technology (Autonomous), Sheriguda, Ibrahimpatnam, Hyderabad.
4MuKtar Jeylan Alo ,Lecturer, Department of Civil Engineering, Madda walabu University, Bale Robe, Ethiopia.
5L.Ranganath, 1Assistant professor . Dept. of Mechanical Engineering, Koneru Lakshmaiah Education Foundation, Vaddeswaram, Guntur, Andhra Pradesh, India.

Manuscript received on November 17., 2019. | Revised Manuscript received on November 24 2019. | Manuscript published on 30 November, 2019. | PP: 12415-12424 | Volume-8 Issue-4, November 2019. | Retrieval Number: D8590118419/2019©BEIESP | DOI: 10.35940/ijrte.D8590.118419

Open Access | Ethics and Policies | Cite  | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: The beam column joint is the most crucial zone in a fortified solid minute opposing edge. Its principle work is to empower the bordering individuals to create and manage their definitive quality. Under seismic stacking, the shot of shear disappointment which is weak in nature is high and isn’t adequate. In this way, the plan and specifying ought to be done appropriately to oppose these seismic burdens. Considering the natural impacts delivered by bond, a compelling option named geo-polymer concrete integrated from side-effects of steel and warm power plants, is in effect broadly utilized and furthermore have indicated demonstrated enhanced after effects of increment in quality properties like compressive, split elasticity and flexural quality of basic individuals as indicated by late investigations. This paper presents conduct of geo-polymer solid inside pillar segment joint fortified with glass filaments which when consistently circulated over its whole mass, gets reinforced tremendously, along these lines rendering the framework to carry on as a composite material with properties altogether unique in relation to regular cement is tried tentatively under cyclic stacking and is thought about systematically utilizing ANSYS.
Keywords: Geo-polymer, Glass fibre, ANSYS, Load cell, UPV Test etc.
Scope of the Article: GEOTECH Engineering.