Loading

CFD Analysis of Auditorium using Ansys Fluent
U. V. Narayana Rao1, K. Srinivasa Rao2, A. Dattatreya Kumar3, G. Yaswanth Kumar4, G. Sridhar Babu5 

1U V Narayana Rao, Department of Civil Engineering V R Siddhartha Engineering College, Vijayawada, India.
2K Srinivasa Rao, Department of Mechanical Engineering V R Siddhartha Engineering College, Vijayawada, India.
3A Dattatreya Kumar, Department of Civil Engineering V R Siddhartha Engineering College, Vijayawada, India.
4G Yaswanth Kumar Department of Civil Engineering V R Siddhartha Engineering College, Vijayawada, India.
5G Sridhar Babu., Department of Mechanical Engineering, V R Siddhartha Engineering College, Vijayawada, India.
Manuscript received on 12 March 2019 | Revised Manuscript received on 17 March 2019 | Manuscript published on 30 July 2019 | PP: 4533-4538 | Volume-8 Issue-2, July 2019 | Retrieval Number: A9249058119/19©BEIESP | DOI: 10.35940/ijrte.A9249.078219
Open Access | Ethics and Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: The primary aspect of any building design and management is heating, ventilation and air conditioning (HVAC). Such systems play very important role in building construction and then the comfort of the occupants of buildings. Hence proper design of such HVAC system is necessary and is essential for efficient and green buildings the HVAC equipment perform the duty of heating and/ or cooling for residential and commercial buildings. Such HVAC system also provide fresh outdoor air to dilute the air contaminants such as odor from occupants of buildings, volatile organic compounds, chemicals etc. Air conditioning equipment is one of the major components in HVAC system. In the project work, an effort has been made to analyses the HVAC system used in seminar halls of which have sitting capacity of 100 people. It is very much essential to have comfortless for people participating in events like seminar, conferences, commercial presentations in seminar hall. Good cooling of seminar hall is essential especially in summer season and moderate warmness is necessary in winter season. In sitting arrangements, the 10 chairs are arranged in 10 rows. The Computational Fluid Dynamic analysis of HVAC system available in seminar hall is carried out by using ANSYS FLUENT software both summer and winter seasons. Parameter studies have been carried out by varying inlet velocity of air in the range 0.1 to 0.5 m/s. the results have been presented in the form of velocity, pressure and temperature contours. As it is observed that as inlet air velocity increases from 0.1 to 0.5 m/s. the outlet temperature decreases from 307 to 302 K.
Keywords: Air Conditioning Organic Compounds, Chemicals etc.
Scope of the Article: Bio – Science and Bio – Technology