Loading

Analysis on Sensitivity of Semiconductor Methane Gas Sensors by Ultrasonic Process
Dae Hwan Kwon1, Suel Ki Choi2, Gyou Tae Park3, Chul Hee Yu4, Geun Jun Lyu5

1Daehwan Kwon*, Institute of Gas Safety R&D Korea Gas Safety Corporation, Wongjung-ro, Maengdong-myon, Eumsung-gun, Chungcheongbuk-do, South Korea.
2Suel Ki Choi, Institute of Gas Safety R&D Korea Gas Safety Corporation, Wongjung-ro, Maengdong-myon, Eumsung-gun, Chungcheongbuk, South Korea.
3Gyou Tae Park, Institute of Gas Safety R&D Korea Gas Safety Corporation, Wongjung-ro, Maengdong-myon, Eumsung-gun, Chungcheongbuk, South Korea.
4Chul Hee Yu, Institute of Gas Safety R&D Korea Gas Safety Corporation,  Wongjung-ro, Maengdong-myon, Eumsung-gun, Chungcheongbuk ,South Korea.
5Geun Jun Lyu, Institute of Gas Safety R&D Korea Gas Safety Corporation, Wongjung-ro, Maengdong-myon, Eumsung-gun, Chungcheongbuk, South Korea.

Manuscript received on April 02, 2020. | Revised Manuscript received on April 15, 2020. | Manuscript published on May 30, 2020. | PP: 176-180 | Volume-9 Issue-1, May 2020. | Retrieval Number: A1210059120/2020©BEIESP | DOI: 10.35940/ijrte.A1210.059120
Open Access | Ethics and Policies | Cite | Mendeley
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: The thin films of Pt and Zn were coated with on the electrode in the board. Thin films of Pt are fabricated by ion plasma and Zn is manufactured by DC sputtering methods. Then the deposited boards were produced by ultrasonic chemical deposition in 0.01 M aqueous solution of C6H12N4 and Zn(NO3)2∙6H2O. To make the ZnO prepared-substrates were heat-treated at 600 °C for 1 hour and the sensitivity of ZnO-structured sensors was tested for Methane gas. In the experiment, the concentrations of Methane gas ranged from 15% to 40% LEL. We measured the change of the voltage before and after the Methane gas injections to judge whether it had a suitable performance as the Methane gas sensors. As a result of the sensitivity of the fabricated sensor, it was found that the voltage increases according to the Methane concentration. The sensitivity of the sensor constantly increased, so the graph showed a linear shape. Also, the fabricated sensors showed very short stabilization time, fast reaction and recovery. As a result, the using possibility of the detector is suggested where detection is required. 
Keywords: Heat-treatment, ZnO, Nano-Structure, Sensitivity, Methane gas, Ultrasonic Chemical Deposition.
Scope of the Article: Analysis of Algorithms and Computational Complexity