Loading

Application of Frequency based Matrix Converter in Wind Energy Conversion System Employing Synchronous Generator Using SVPWM Method
P. Jeyalakshmi1, M. Siva Ramkumar2, IR.V. Mansoor3, A. Amudha4, G. Emayavaramban5, D. Kavitha6, M. Sivaram Krishnan7

1P. Jeyalakshmi, Department of EEE, Karpagam Academy of Higher Education, Coimbatore (Tamil Nadu), India.
2Dr. M. Siva Ramkumar, Asst Professor & Head, Department of EEE, Karpagam Academy of Higher Education, Coimbatore (Tamil Nadu), India.
3Dr. IR.V. Mansoor, Asst Professor & Head, Department of EEE, Karpagam Academy of Higher Education, Coimbatore (Tamil Nadu), India.
4Dr. A. Amudha, Professor & Head, Department of EEE, Karpagam Academy of Higher Education, Coimbatore (Tamil Nadu), India.
5Dr. G. Emayavaramban, Asst Professor & Head, Department of EEE, Karpagam Academy of Higher Education, Coimbatore (Tamil Nadu), India.
6D. Kavitha, Asst Professor, Department of EIE, SNS college of Technology, Coimbatore (Tamil Nadu), India.
7M. Sivaram Krishnan, Asst Professor, Department of EEE, Karpagam College of Engineering, Coimbatore (Tamil Nadu), India.
Manuscript received on 03 June 2019 | Revised Manuscript received on 28 June 2019 | Manuscript Published on 04 July 2019 | PP: 187-195 | Volume-8 Issue-1S4 June 2019 | Retrieval Number: A10370681S419/2019©BEIESP
Open Access | Editorial and Publishing Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: Renewable energy is garnering the attention of people with rising global energy consumption and perceivable environmental pollution all across the universe. The rising size of wind farms needs power system stability analysis [7] inclusive of dynamic wind generator models. In the case of turbines with power greater than 1MW, doubly-fed induction machines are the most popularly utilized concept. But, direct-drive wind generators that depend on converter-driven synchronous generator concepts [11] have attained substantial penetration in the market. This research work introduces converter driven synchronous generator model utilizing frequency based matrix converter [9] with the aid of SVPWM approach [6] and the parameters such as stator and grid voltage/current are measured and the overall THD of the system is analyzed. The matrix converter with frequency based technique is utilized for converting the variable voltage to a stable value, which can be connected to a grid.
Keywords: SVPWM, THD, Matrix Converter, Synchronous Generator, MATLAB/SIMULINK.
Scope of the Article: Economics of Energy Harvesting Communications