Loading

Voltage & Frequency Stabilisation of A Hybrid Micro Grid Framework using Sliding Mode Controller
Abhijeet Choudhury1, Amar Bijay Nanda2, Amiya Kumar Naik3, Swagat Pati4, Sanjeeb Kumar Kar5
1Abhijeet Choudhury, Department of Electrical Engineering, ITER, Siksha „O‟ Anusandhan (Deemed to be University), Bhubaneswar, India.
2Amar Bijay Nanda, Department of Electrical Engineering, ITER, Siksha „O‟ Anusandhan (Deemed to be University), Bhubaneswar, India.
3Amiya Kumar Naik, Department of Electrical Engineering, ITER, Siksha „O‟ Anusandhan (Deemed to be University), Bhubaneswar, India.
4Swagat Pati, Department of Electrical Engineering, ITER, Siksha „O‟ Anusandhan (Deemed to be University), Bhubaneswar, India.
5Sanjeeb Kumar Kar, Department of Electrical Engineering, ITER, Siksha „O‟ Anusandhan (Deemed to be University), Bhubaneswar, India. 

Manuscript received on November 11, 2019. | Revised Manuscript received on November 20 2019. | Manuscript published on 30 November, 2019. | PP: 10758-10765 | Volume-8 Issue-4, November 2019. | Retrieval Number: D4344118419/2019©BEIESP | DOI: 10.35940/ijrte.D4344.118419

Open Access | Ethics and Policies | Cite  | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: In this paper an extemporized micro grid system is considered, which is capable of supplying power to different time varying loads. The framework considered in this work comprises of different sources for example a consistent power miniaturized scale micro-hydro system, a wind energy conversion system equipped with Battery Energy Storage System. The consistent power smaller scale micro-hydro houses a 22KW SEIG which conveys capacity to the local time varying loads. The BESS is associated at the DC connection of the Wind Energy Conversion System. Grid Side Converter of the Wind Energy Conversion System acts like a STATCOM. During different stacking conditions, the active and reactive power created by the SEIG isn’t adequate, in this way there is a negligible change in frameworks of voltage and frequency. In this way Grid Side Converter conveys the necessary capacity to the system keeps up the frequency and voltage to be consistent and improves power quality in the system. The Grid Side Converter likewise deals with the active power intensity of the system by putting away the overabundance power in the BESS and providing it when required in the evening time. Different sorts of loads, for example, Linear RL load, Non-Linear load, and Dynamic load are considered to assess the exhibition of the hybrid autonomous system. The above simulation is finished utilizing MATLAB/Simulink condition.
Keywords: Self Excited Induction Generator (SEIG); Doubly Fed Induction Generator (DFIG), Static Synchronous Compensator (STATCOM), Decoupled Control, Battery Energy Storage System (BESS), Non-Linear Load, Dynamic Load.
Scope of the Article: Frequency Selective Surface.