Loading

Power System Security by FACTS Devices using GA
Chandrashekhar S. Hiwarkar1, Prakash G. Burade2

1Chandrashekhar S. Hiwarkar, Research Scholar, Priyadarshini College of Engineering, Nagpur (Maharashtra), India.
2Dr. Prakash G. Burade, Professor & Head, Department of Electrical Engineering, SITRC, Nashik (Maharashtra), India.
Manuscript received on 25 August 2019 | Revised Manuscript received on 11 September 2019 | Manuscript Published on 17 September 2019 | PP: 1876-1882 | Volume-8 Issue-2S8 August 2019 | Retrieval Number: B11930882S819/2019©BEIESP | DOI: 10.35940/ijrte.B1193.0882S819
Open Access | Editorial and Publishing Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: Now daily’s electrical power necessity has expanded exponentially while the development and rebuilding of the electrical power framework for age and transmission in the power segment has been basically restricted because of present assets and natural conditions. Accordingly, roughly of the halls of power transmission overhead lines are intensely stacked and clogged. Additionally the serious issue of power framework voltage dependability turns into a power move constraining and capacity factor. A Modern power electronics innovation FATCS based gadget Static Synchronous Series Compensator (SSSC) is a VSC based series FACTS gadget. Bound together power flow controller (UPFC) is to control power flow, voltage magnitude, and phase point. In this examination paper proposed to keep up the voltage magnitude just as power flow of broken lines. The result of change of the power framework parameters, for example, voltage, phase point, dynamic power, responsive power, and in general power factor with and without SSSC and UPFC have additionally been consolidated. Assessment of power framework security is important in the public arena to create approaches to keep up framework activity when at least one segments come up short. A power framework is “secure” when it can resist the loss of at least one fixings and still continue working without serious issues. The Contingency occasion examination strategy is taken to recognize electrical hub power flow in the flawed transmission lines. The Performance of power framework is checked on IEEE 14-Bus System.
Keywords: SSSC, UPFC, Contingency Technique, Power Flow.
Scope of the Article: Low-power design