Performance and Optimization of Commercial Solar PV and PTC Plants
M.A. Baseer1, Praveen R. P2, M. Zubair3, A. Galal Abo Khalil4, Ibrahim Al Saduni5
1M.A. Baseer, Department of Electrical Engineering, Majmaah University, Saudi Arabia.
2Praveen R. P, Department of Electrical Engineering, Majmaah University, Saudi Arabia.
3M. Zubair, Department of Electrical Engineering, Majmaah University, Saudi Arabia.
4A. Galal Abo Khalil, Department of Electrical Engineering, Majmaah University, Saudi Arabia.
5Ibrahim Al Saduni, Department of Electrical Engineering, Majmaah University, Saudi Arabia.

Manuscript received on January 02, 2020. | Revised Manuscript received on January 15, 2020. | Manuscript published on January 30, 2020. | PP: 1703-1714 | Volume-8 Issue-5, January 2020. | Retrieval Number: E6247018520/2020©BEIESP | DOI: 10.35940/ijrte.E6247.018520

Open Access | Ethics and Policies | Cite | Mendeley
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: Installation of solar PV arrays at utility scale is gaining popularity nowadays because of the significant reduction in the cost of components as well as the global push towards clean energy. Solar PV plants along with Parabolic Trough Collector Solar thermal plants has the highest potential among the available Renewable Energy (RE) technologies existing in the world. The objective of this paper is to optimize the performance of commercial Solar PV and PTC power plant for a potential location and hence to arrive on a most feasible configuration for the site. A representative site located in the Abudhabi region of UAE considered for the study. This paper also details on the annual performance of the proposed plant along with its technical aspects. PVSYST 6.7.7 and SAM software is used to design the optimal size and its specifications of a 100MW PV grid connected system at Abu Dhabi (UAE) region. The design and arrangements of the system verified using simulation results. The annual energy generated from the designed utility-scale solar PV plant from PVSYST 6.7.7 calculated as 161198MWh/year with a performance ratio (PR) of 74.8% per year where as for PTC it has calculated as 157152MWh/year by using SAM. The STC (Standard Testing Condition) for the specification of PV modules are normalized operating conditions when testing the module. Design parameters such as module orientation, array yield, reference yield, final yield, global horizontal irradiation (GHI), and ambient temperature and loss factors evaluated. To evaluate the economic feasibility of proposed plant, the levelized cost of electricity (LCOE) is determined as $0.04404/kwh for Solar PV and as $0.01533/kwh for PTC, which is used to calculate lifecycle cost and energy production.
Keywords: Solar PV Power Plants, Grid Connected System, PVSYST, SAM, GHI, Annual Plants Electricity Generation.
Scope of the Article: Cyber Physical Systems (CPS).